AC DC Configurable Power Supply Chassis
Mfr Part # | Quantity Available | Price | Series | Package | Product Status | User Configuration | Type | Number of Positions | Voltage - Input | Power (Watts) | Voltage - Isolation | Efficiency | Features | Operating Temperature | Size / Dimension | Height | Approval Agency | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
164 In Stock | 1 : 399,77000 € Box | Box | Active | - | Medical | 6 | 85 ~ 264 VAC | 1200 W | 4 kV | 90% | - | -40°C ~ 70°C (With Derating) | 10.24" L x 5.00" W (260.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | |||
32 In Stock | 1 : 571,00000 € Bulk | Bulk | Active | - | Standard | 6 | 85 ~ 264 VAC | 1200 W | 3 kV | 90% | - | -20°C ~ 70°C | 10.24" L x 5.00" W (260.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | |||
34 In Stock | 1 : 617,25000 € Box | Box | Active | - | Standard | 6 | 85 ~ 264 VAC | 1340 W | 3 kV | 90% | - | -20°C ~ 70°C | 10.55" L x 5.00" W (268.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | |||
14 In Stock 13 Marketplace | 1 : 346,31000 € Box 1 : 254,49000 € Bulk | Bulk Box | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 90% | - | -40°C ~ 70°C (With Derating) | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | |||
6 In Stock | 1 : 335,18000 € Bulk | Bulk | Active | - | Standard | 4 | 85 ~ 264 VAC | 400 W | 3 kV | 89% | - | -20°C ~ 70°C | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | |||
5 In Stock | 1 : 335,20000 € Bulk | Bulk | Active | - | Standard | 4 | 85 ~ 264 VAC | 400 W | 3 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | |||
12 In Stock | 1 : 506,31000 € Bulk | Bulk | Active | - | Standard | 6 | 85 ~ 264 VAC | 1000 W | 3 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C | 10.24" L x 5.00" W (260.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | |||
6 In Stock | 1 : 506,31000 € Bulk | Bulk | Active | - | Standard | 6 | 85 ~ 264 VAC | 1000 W | 3 kV | 90% | - | -20°C ~ 70°C | 10.24" L x 5.00" W (260.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | |||
14 In Stock | 1 : 526,34000 € Box | Box | Active | - | Medical | 6 | 85 ~ 264 VAC | 700 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | |||
18 In Stock | 1 : 558,68000 € Bulk | Bulk | Active | - | Standard | 6 | 85 ~ 264 VAC | 1200 W | 3 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C | 10.24" L x 5.00" W (260.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | |||
20 In Stock | 1 : 617,25000 € Box | Box | Active | - | Standard | 6 | 85 ~ 264 VAC | 1340 W | 3 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C | 10.55" L x 5.00" W (268.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | |||
21 In Stock | 1 : 329,68000 € Bulk | Bulk | Active | - | Standard | 4 | 85 ~ 264 VAC | 200 W | 3 kV | 89% | - | -20°C ~ 70°C | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | |||
13 In Stock | 1 : 248,82000 € Bulk | Bulk | Active | - | Standard | 4 | 85 ~ 264 VAC | 200 W | 3 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | |||
10 In Stock | 1 : 301,42000 € Box | Box | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | |||
2 In Stock | 1 : 459,88000 € Box | Box | Active | - | Medical | 6 | 85 ~ 264 VAC | 1000 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | |||
6 In Stock | 1 : 474,43000 € Bulk | Bulk | Active | - | Standard | 6 | 85 ~ 264 VAC | 700 W | 3 kV | 90% | - | -20°C ~ 70°C | 10.24" L x 5.00" W (260.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | |||
2 In Stock | 1 : 517,56000 € Box | Box | Active | - | Medical | 6 | 85 ~ 264 VAC | 1200 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | |||
18 In Stock | 1 : 304,37000 € Box | Box | Active | - | Medical | 4 | 85 ~ 264 VAC | 400 W | 4 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | |||
0 In Stock Check Lead Time | 1 : 316,25000 € Bulk | Bulk | Active | - | Standard | 4 | 85 ~ 264 VAC | 600 W | 3 kV | 89% | - | -20°C ~ 70°C | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | |||
0 In Stock Check Lead Time | 1 : 343,40000 € Bulk | Bulk | Active | - | Standard | 4 | 85 ~ 264 VAC | 600 W | 3 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | |||
0 In Stock Check Lead Time | 1 : 443,21000 € Bulk | Bulk | Active | - | Standard | 6 | 85 ~ 264 VAC | 700 W | 3 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C | 10.24" L x 5.00" W (260.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | |||
0 In Stock Check Lead Time | 5 : 377,47000 € Bulk | Bulk | Active | - | Standard | 6 | 85 ~ 264 VAC | 400 W | 3 kV | 90% | - | -20°C ~ 70°C | 10.24" L x 5.00" W (260.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | |||
0 In Stock Check Lead Time | 5 : 264,29800 € Bulk | Bulk | Active | - | Standard | 6 | 85 ~ 264 VAC | 400 W | 3 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C | 10.24" L x 5.00" W (260.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | |||
0 In Stock Check Lead Time | 5 : 268,90800 € Box | Box | Active | - | Medical | 4 | 85 ~ 264 VAC | 200 W | 4 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | |||
0 In Stock Check Lead Time | 5 : 357,83800 € Box | Box | Active | - | Medical | 6 | 85 ~ 264 VAC | 400 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus |